Jump to content

mutayu

Član
  • Broj sadržaja

    1430
  • Na DiyAudio.rs od

  • Poslednja poseta

  • Broj dana (pobeda)

    8

Poslednji trofej

mutayu je imao/la sadržaj sa najviše reakcija!

1 Pratilac

Informacije Profila

  • Pol:
    Muško
  • Lokacija:
    Dojno Polje
  • Zemlja:
    Serbia

Skorašnji posetioci profila

The recent visitors block is disabled and is not being shown to other users.

mutayu's Achievements

Dugo je sa nama

Dugo je sa nama (7/9)

832

Forumska reputacija

  1. 1N4148 nije adekvatna zamena za svaku poziciju. Ako ce da posluzi za probu u redu ali ako menjas trajno definitivno nabavi 1N4448.
  2. Ako se ispostavi da je potrebna zamena diode BA513, direktni ekvivalent je 1N4448. Ima da se kupi u Bg, kosta 2,40 dinara.
  3. Je li to trafo na C jezgrima? Da ga udomim?
  4. Dobri nas Zero, ne razumem se bas ali moram da pitam, zar nije jednostavnije i jeftinije zameniti komp, windows i drajvere masinom i softverom koji ce podrzati novi DAC? Kad je vec talijan takav kakav je i kad se ponasa tako kako se ponasa.
  5. Majstor iz okoline Nis. Poslacu ti broj na Viber.
  6. Pojacalce dobilo odgovarajuce napajanje pa je sad potpuno uskladjeno sa konstruktorovom semom RH84. Sad vise nema cujnog suma ni bruma a svira odlicno. Mozda dobije i kutiju!
  7. Ako bi ih pravilno rasporedili bile bi udaljene oko 5km jedna od druge u svakom pravcu, na celoj teritoriji.
  8. Mole se gosti da ne pipaju stjuardesu s' masni prsti! 😁
  9. U prozorcicu Edit za vrednosti kondenzatora treba postaviti i odgovarajuci series resistance za primenjeni kondenzator. Evo ga i proracun impedanse trafoa iz PSUD2 help-a : Edit Transformer Properties Enter the voltage for the secondary of the transformer. Note that this must be the off-load voltage, which is generally higher than the rated voltage of the transformer. For full wave rectifiers, use the voltage for one side only. For example, if the transformer off load voltage is 350-0-350V (700V end to end), the correct value to enter is 350. Enter the source impedance of the transformer. If you don't know this, you can click on the [...] buttons to invoke the off load voltage calculator, or source impedance calculator respectively. Source Impedance Calculator The source impedance of the transformer is required in order to simulate the transformer "sagging" under load. Supply voltage: (VP) The voltage primary supply into the transformer, normally 110/115/220/230/240 volts. Winding resistance: (RP) The measured resistance of the primary winding. Off-load voltage: (VS) The measured voltage on the secondary of the transformer before any load is applied. Winding resistance: (RS) The measured resistance of the secondary winding. Resistance for simulation: R.equiv = ((VS/VP) x RP) + RS
  10. Stara Ei Melodija je postala RH84. Doduse sa switcherskim napajanjem i regulatorima pa susti kao luda. RH.jpg.heic
  • Trenutno na sajtu   0 članova, 0 Skrivenih, 46 Gosta (Pogledaj celu listu)

    • There are no registered users currently online
  • Forumska statistika

    9.2k
    Ukupan broj tema
    452.7k
    Ukupan broj objava
  • Statistika članovȃ

    3024
    Svi članovi
    5071
    Najviše na sajtu
    katarina.la
    Najnoviji član
    katarina.la
    se pridružio
×
×
  • Kreiraj novo...