Okay,Outputs removed, input shorted, output shorted.
DC to 15.5v
Changed R35 to 180R, reads 1.8v
Changed R23 to 47R, still reads 0V
R3 to 9.4v
R12 and R25 to 0R
4.7R's all read 23.5mv, all 2SJ74's show 10.4v
R26 is 2.0v
Replaced opto-coupler as well, and Q7.
Thanks a bunch, and rest well. I am no rush here.
One oddity I have noticed is that with R27 installed (33R), the gate to Drain shorts, with R100 installed or not. I don't forsee it causing this issue, but,
I cannot repeat this on the working channel.